Product outline
- Delivers ANSI/TIA-568.2-D Cat6 permanent link performance up to 50m, ideal for small and medium size installations
- Space-saving U/UTP design, enabling reliable wired networks to the places other systems can’t reach
- Reducing bundle sizes by almost half (cross-sectional area)
- IEEE802.3bt 100W PoE++ capable
- Simultaneous UL444 CM and CPR Dca fire rating for full compliance with US and EU safety requirements
- Conveniently packaged in a Reel-in-Box delivery system that’s easy to identify in a van or on site
- AS/NZS S008:2010 compliant
- RoHS compliant
- Kordz Lifetime Warranty
Technical info
CONSTRUCTION
Conductor: 28AWG solid OFC 0.338 +0/-0.02mm
Insulation: Polyethylene, 0.61±0.1 mm
Twisting: 4 Twisted pairs of conductors, not bonded
Twisted Pair Colour Code: 1: white / blue 2: white-orange / orange 3: white / green 4: white-brown / brown
Shielding: Unshielded (U/UTP)
Jacket Material: FRLSZH composite
Outer Diameter: 4.0 ± 0.5 mm
MECHANICAL
Minimum Bend Radius: Without load ≥ 16.0 mm; with load ≥ 32.0 mm
Temperature Range: During operation -20 °C to 60°C; During installation 0°C to 50°C
ELECTRICAL
DC Resistance: Max. 23.6 Ω/100 m at 20°C
Resistance Unbalance: Max. 4% at 20°C
Insulation Resistance (500V): Min. 5000 MΩ/km at 20°C
Mutual Capacitance: Max. 5.6 nf/100 m at 1 kHz
Capacitance Unbalance (Pair to ground): Max. 330 pf/100 m at 1 kHz
Nominal Velocity of Propagation: Nom. 67%
Test Voltage (DC, 1min): 1 kV / 1 min